Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44.615
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
BMC Med Imaging ; 24(1): 77, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566000

RESUMO

BACKGROUND: To investigate the value of a nomogram model based on the combination of clinical-CT features and multiphasic enhanced CT radiomics for the preoperative prediction of the microsatellite instability (MSI) status in colorectal cancer (CRC) patients. METHODS: A total of 347 patients with a pathological diagnosis of colorectal adenocarcinoma, including 276 microsatellite stabilized (MSS) patients and 71 MSI patients (243 training and 104 testing), were included. Univariate and multivariate regression analyses were used to identify the clinical-CT features of CRC patients linked with MSI status to build a clinical model. Radiomics features were extracted from arterial phase (AP), venous phase (VP), and delayed phase (DP) CT images. Different radiomics models for the single phase and multiphase (three-phase combination) were developed to determine the optimal phase. A nomogram model that combines clinical-CT features and the optimal phasic radscore was also created. RESULTS: Platelet (PLT), systemic immune inflammation index (SII), tumour location, enhancement pattern, and AP contrast ratio (ACR) were independent predictors of MSI status in CRC patients. Among the AP, VP, DP, and three-phase combination models, the three-phase combination model was selected as the best radiomics model. The best MSI prediction efficacy was demonstrated by the nomogram model built from the combination of clinical-CT features and the three-phase combination model, with AUCs of 0.894 and 0.839 in the training and testing datasets, respectively. CONCLUSION: The nomogram model based on the combination of clinical-CT features and three-phase combination radiomics features can be used as an auxiliary tool for the preoperative prediction of the MSI status in CRC patients.


Assuntos
Neoplasias Colorretais , Nomogramas , Humanos , Instabilidade de Microssatélites , 60570 , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/genética , Neoplasias Colorretais/cirurgia
2.
Gen Dent ; 72(3): 50-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640006

RESUMO

The objective of this retrospective study was to assess the bone quality of healing mandibular fracture sites by measuring the Hounsfield units (HU) on computed tomographic (CT) images obtained presurgery and postsurgery in patients treated with rigid internal fixation (RIF). The HU values of healing fracture sites were compared to those of corresponding nonfractured (control) sites on the opposing side and cervical vertebrae sites in the same patients. In total, 31 patients with 45 mandibular fractures treated with RIF underwent presurgical and postsurgical CT examinations. The scans performed after surgery (1, 3, 6, 12, or 18 months) were taken only when there was a need for radiographic evaluation due to a complaint of discomfort from the patient or when the surgeon needed to verify the postsurgical outcome, and each patient underwent only a single postsurgical CT. At the presurgical CT examination, the HU values were lower in the fracture sites than in the control sites. At 3 months postsurgery, the HU values in the fracture sites had increased as the mandibular bone healed. At 6 months postsurgery, the HU values in the fracture sites were higher than those of the control sites. At 12 and 18 months postsurgery, the HU values of both sites were similar. The HU values of the cervical vertebrae remained constant with time. These results suggest that, in patients who have been treated with RIF for mandibular bone fracture, HU values measured by CT vary across time, expressing the physiologic bone healing process.


Assuntos
Densidade Óssea , Fraturas Mandibulares , Humanos , Estudos Retrospectivos , Densidade Óssea/fisiologia , Fraturas Mandibulares/diagnóstico por imagem , Fraturas Mandibulares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Tomografia
3.
J Thorac Imaging ; 39(3): 194-199, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38640144

RESUMO

PURPOSE: To develop and evaluate a deep convolutional neural network (DCNN) model for the classification of acute and chronic lung nodules from nontuberculous mycobacterial-lung disease (NTM-LD) on computed tomography (CT). MATERIALS AND METHODS: We collected a data set of 650 nodules (316 acute and 334 chronic) from the CT scans of 110 patients with NTM-LD. The data set was divided into training, validation, and test sets in a ratio of 4:1:1. Bounding boxes were used to crop the 2D CT images down to the area of interest. A DCNN model was built using 11 convolutional layers and trained on these images. The performance of the model was evaluated on the hold-out test set and compared with that of 3 radiologists who independently reviewed the images. RESULTS: The DCNN model achieved an area under the receiver operating characteristic curve of 0.806 for differentiating acute and chronic NTM-LD nodules, corresponding to sensitivity, specificity, and accuracy of 76%, 68%, and 72%, respectively. The performance of the model was comparable to that of the 3 radiologists, who had area under the receiver operating characteristic curve, sensitivity, specificity, and accuracy of 0.693 to 0.771, 61% to 82%, 59% to 73%, and 60% to 73%, respectively. CONCLUSIONS: This study demonstrated the feasibility of using a DCNN model for the classification of the activity of NTM-LD nodules on chest CT. The model performance was comparable to that of radiologists. This approach can potentially and efficiently improve the diagnosis and management of NTM-LD.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Pneumonia , Humanos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagem
4.
BMJ Open Respir Res ; 11(1)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589197

RESUMO

BACKGROUND: Diagnosing mediastinal tumours, including incidental lesions, using low-dose CT (LDCT) performed for lung cancer screening, is challenging. It often requires additional invasive and costly tests for proper characterisation and surgical planning. This indicates the need for a more efficient and patient-centred approach, suggesting a gap in the existing diagnostic methods and the potential for artificial intelligence technologies to address this gap. This study aimed to create a multimodal hybrid transformer model using the Vision Transformer that leverages LDCT features and clinical data to improve surgical decision-making for patients with incidentally detected mediastinal tumours. METHODS: This retrospective study analysed patients with mediastinal tumours between 2010 and 2021. Patients eligible for surgery (n=30) were considered 'positive,' whereas those without tumour enlargement (n=32) were considered 'negative.' We developed a hybrid model combining a convolutional neural network with a transformer to integrate imaging and clinical data. The dataset was split in a 5:3:2 ratio for training, validation and testing. The model's efficacy was evaluated using a receiver operating characteristic (ROC) analysis across 25 iterations of random assignments and compared against conventional radiomics models and models excluding clinical data. RESULTS: The multimodal hybrid model demonstrated a mean area under the curve (AUC) of 0.90, significantly outperforming the non-clinical data model (AUC=0.86, p=0.04) and radiomics models (random forest AUC=0.81, p=0.008; logistic regression AUC=0.77, p=0.004). CONCLUSION: Integrating clinical and LDCT data using a hybrid transformer model can improve surgical decision-making for mediastinal tumours, showing superiority over models lacking clinical data integration.


Assuntos
Neoplasias Pulmonares , Neoplasias do Mediastino , Humanos , Neoplasias Pulmonares/patologia , Inteligência Artificial , Neoplasias do Mediastino/diagnóstico por imagem , Estudos Retrospectivos , Detecção Precoce de Câncer , Tomografia Computadorizada por Raios X/métodos
5.
Cell Rep Med ; 5(4): 101486, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38631288

RESUMO

PET scans provide additional clinical value but are costly and not universally accessible. Salehjahromi et al.1 developed an AI-based pipeline to synthesize PET images from diagnostic CT scans, demonstrating its potential clinical utility across various clinical tasks for lung cancer.


Assuntos
Neoplasias Pulmonares , Humanos , Fluordesoxiglucose F18 , Tomografia Computadorizada por Raios X/métodos , Prognóstico , Inteligência Artificial
7.
Cancer Imaging ; 24(1): 47, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566150

RESUMO

PURPOSE: To investigate the computed tomography (CT) characteristics of air-containing space and its specific patterns in neoplastic and non-neoplastic ground glass nodules (GGNs) for clarifying their significance in differential diagnosis. MATERIALS AND METHODS: From January 2015 to October 2022, 1328 patients with 1,350 neoplastic GGNs and 462 patients with 465 non-neoplastic GGNs were retrospectively enrolled. Their clinical and CT data were analyzed and compared with emphasis on revealing the differences of air-containing space and its specific patterns (air bronchogram and bubble-like lucency [BLL]) between neoplastic and non-neoplastic GGNs and their significance in differentiating them. RESULTS: Compared with patients with non-neoplastic GGNs, female was more common (P < 0.001) and lesions were larger (P < 0.001) in those with neoplastic ones. Air bronchogram (30.1% vs. 17.2%), and BLL (13.0% vs. 2.6%) were all more frequent in neoplastic GGNs than in non-neoplastic ones (each P < 0.001), and the BLL had the highest specificity (93.6%) in differentiation. Among neoplastic GGNs, the BLL was more frequently detected in the larger (14.9 ± 6.0 mm vs. 11.4 ± 4.9 mm, P < 0.001) and part-solid (15.3% vs. 10.7%, P = 0.011) ones, and its incidence significantly increased along with the invasiveness (9.5-18.0%, P = 0.001), whereas no significant correlation was observed between the occurrence of BLL and lesion size, attenuation, or invasiveness. CONCLUSION: The air containing space and its specific patterns are of great value in differentiating GGNs, while BLL is a more specific and independent sign of neoplasms.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Humanos , Feminino , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/patologia , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Diferencial
8.
Eur Radiol Exp ; 8(1): 50, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38570418

RESUMO

BACKGROUND: Heartbeat-based cross-sectional area (CSA) changes in the right main pulmonary artery (MPA), which reflects its distensibility associated with pulmonary hypertension, can be measured using dynamic ventilation computed tomography (DVCT) in patients with and without chronic obstructive pulmonary disease (COPD) during respiratory dynamics. We investigated the relationship between MPA distensibility (MPAD) and respiratory function and how heartbeat-based CSA is related to spirometry, mean lung density (MLD), and patient characteristics. METHODS: We retrospectively analyzed DVCT performed preoperatively in 37 patients (20 female and 17 males) with lung cancer aged 70.6 ± 7.9 years (mean ± standard deviation), 18 with COPD and 19 without. MPA-CSA was separated into respiratory and heartbeat waves by discrete Fourier transformation. For the cardiac pulse-derived waves, CSA change (CSAC) and CSA change ratio (CSACR) were calculated separately during inhalation and exhalation. Spearman rank correlation was computed. RESULT: In the group without COPD as well as all cases, CSACR exhalation was inversely correlated with percent residual lung volume (%RV) and RV/total lung capacity (r = -0.68, p = 0.003 and r = -0.58, p = 0.014). In contrast, in the group with COPD, CSAC inhalation was correlated with MLDmax and MLD change rate (MLDmax/MLDmin) (r = 0.54, p = 0.020 and r = 0.64, p = 0.004) as well as CSAC exhalation and CSACR exhalation. CONCLUSION: In patients with insufficient exhalation, right MPAD during exhalation was decreased. Also, in COPD patients with insufficient exhalation, right MPAD was reduced during inhalation as well as exhalation, which implied that exhalation impairment is a contributing factor to pulmonary hypertension complicated with COPD. RELEVANCE STATEMENT: Assessment of MPAD in different respiratory phases on DVCT has the potential to be utilized as a non-invasive assessment for pulmonary hypertension due to lung disease and/or hypoxia and elucidation of its pathogenesis. KEY POINTS: • There are no previous studies analyzing all respiratory phases of right main pulmonary artery distensibility (MPAD). • Patients with exhalation impairment decreased their right MPAD. • Analysis of MPAD on dynamic ventilation computed tomography contributes to understanding the pathogenesis of pulmonary hypertension due to lung disease and/or hypoxia in patients with expiratory impairment.


Assuntos
Hipertensão Pulmonar , Pneumopatias , Doença Pulmonar Obstrutiva Crônica , Masculino , Humanos , Feminino , Artéria Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/complicações , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/complicações , Tomografia Computadorizada por Raios X/métodos , Hipóxia/complicações
9.
J Cardiothorac Surg ; 19(1): 173, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575975

RESUMO

BACKGROUND: Sinus histiocytosis with massive lymphadenopathy, also known as Rosai-Dorfman disease, is a rare, self-limiting disease that predominantly affects children and young adults. Moreover, the disease is characterized by painless bilateral cervical lymphadenopathy in 95% of the patients. However, few reports are available on the Rosai-Dorfman disease of the thymus. CASE PRESENTATION: We report a rare case of thymic Rosai-Dorfman disease detected using computed tomography. During a medical examination, a 50-year-old man underwent a chest computed tomography scan, which revealed an anterior mediastinal single mass with fat in the thymus. A thymectomy was performed to completely remove the tumor using a thoracoscopic technique due to a clinical suspicion of thymoma. Furthermore, Rosai-Dorfman disease was confirmed using histological and immunohistochemical analyses. CONCLUSIONS: To the best of our knowledge, this is the sixth case of thymus-affecting solitary Rosai-Dorfman disease with histological and immunohistochemical evidence. Fat in the thymus, as was present in this case, has never been described in Rosai-Dorfman disease previously. Our results highlight the challenge of diagnosing this uncommon tumor before surgery, and more cases need to be reported to help with the preoperative diagnosis of such a rare tumor.


Assuntos
Histiocitose Sinusal , Doenças do Mediastino , Neoplasias , Masculino , Criança , Humanos , Pessoa de Meia-Idade , Histiocitose Sinusal/diagnóstico , Histiocitose Sinusal/cirurgia , Histiocitose Sinusal/patologia , Tomografia Computadorizada por Raios X/métodos , Doenças do Mediastino/diagnóstico , Diagnóstico Diferencial
10.
Medicine (Baltimore) ; 103(14): e37704, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579068

RESUMO

BACKGROUND: Posterior mediastinal leiomyosarcoma is an extremely rare malignant mesenchymal tumor with no special clinical symptoms, which is easily confused with some common tumors in the posterior mediastinum, affecting the accuracy of the first diagnosis by clinicians and delaying the treatment of patients. CASE SUMMARY: We report a 59-year-old woman with a space-occupying lesion in the posterior mediastinum. The patient was mistakenly diagnosed with lumbar muscle or vertebral body lesions due to chest and back pain and underwent conservative treatment, but her symptoms did not improve significantly and she gradually developed pain in both lower limbs. Chest computed tomography (CT) scan indicated the left lower lung paraspinal space and underwent standard single-aperture video-assisted thoracoscopic surgery (VATS), which was pathologically confirmed as posterior mediastinal leiomyosarcoma. CONCLUSION: Complete surgical resection of posterior mediastinal leiomyosarcoma can achieve good clinical results.


Assuntos
Leiomiossarcoma , Neoplasias do Mediastino , Humanos , Feminino , Pessoa de Meia-Idade , Mediastino/patologia , Leiomiossarcoma/diagnóstico , Leiomiossarcoma/cirurgia , Leiomiossarcoma/patologia , Neoplasias do Mediastino/diagnóstico , Neoplasias do Mediastino/cirurgia , Neoplasias do Mediastino/patologia , Tórax/patologia , Tomografia Computadorizada por Raios X/métodos
11.
J Cardiothorac Surg ; 19(1): 182, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581004

RESUMO

PURPOSE: In VATS surgery, precise preoperative localization is particularly crucial when dealing with small-diameter pulmonary nodules located deep within the lung parenchyma. The purpose of this study was to compare the efficacy and safety of laser guidance and freehand hook-wire for CT-guided preoperative localization of pulmonary nodules. METHODS: This retrospective study was conducted on 164 patients who received either laser guidance or freehand hook-wire localization prior to Uni-port VATS from September 1st, 2022 to September 30th, 2023 at The First Affiliated Hospital of Soochow University. Patients were divided into laser guidance group and freehand group based on which technology was used. Preoperative localization data from all patients were compiled. The localization success and complication rates associated with the two groups were compared. The risk factors for common complications were analyzed. RESULTS: The average time of the localization duration in the laser guidance group was shorter than the freehand group (p<0.001), and the average CT scan times in the laser guidance group was less than that in the freehand group (p<0.001). The hook-wire was closer to the nodule in the laser guidance group (p<0.001). After the localization of pulmonary nodules, a CT scan showed 14 cases of minor pneumothorax (22.58%) in the laser guidance group and 21 cases (20.59%) in the freehand group, indicating no statistical difference between the two groups (p=0.763). CT scans in the laser guidance group showed pulmonary minor hemorrhage in 8 cases (12.90%) and 6 cases (5.88%) in the freehand group, indicating no statistically significant difference between the two groups (p=0.119). Three patients (4.84%) in the laser guidance group and six patients (5.88%) in the freehand group had hook-wire dislodgement, showing no statistical difference between the two groups (p=0.776). CONCLUSION: The laser guidance localization method possessed a greater precision and less localization duration and CT scan times compared to the freehand method. However, laser guidance group and freehand group do not differ in the appearance of complications such as pulmonary hemorrhage, pneumothorax and hook-wire dislodgement.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Pneumotórax , Nódulo Pulmonar Solitário , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Pneumotórax/cirurgia , Estudos Retrospectivos , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Tomografia Computadorizada por Raios X/métodos , Hemorragia
12.
Cancer Med ; 13(7): e7140, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38581113

RESUMO

BACKGROUND: The exceptional capabilities of artificial intelligence (AI) in extracting image information and processing complex models have led to its recognition across various medical fields. With the continuous evolution of AI technologies based on deep learning, particularly the advent of convolutional neural networks (CNNs), AI presents an expanded horizon of applications in lung cancer screening, including lung segmentation, nodule detection, false-positive reduction, nodule classification, and prognosis. METHODOLOGY: This review initially analyzes the current status of AI technologies. It then explores the applications of AI in lung cancer screening, including lung segmentation, nodule detection, and classification, and assesses the potential of AI in enhancing the sensitivity of nodule detection and reducing false-positive rates. Finally, it addresses the challenges and future directions of AI in lung cancer screening. RESULTS: AI holds substantial prospects in lung cancer screening. It demonstrates significant potential in improving nodule detection sensitivity, reducing false-positive rates, and classifying nodules, while also showing value in predicting nodule growth and pathological/genetic typing. CONCLUSIONS: AI offers a promising supportive approach to lung cancer screening, presenting considerable potential in enhancing nodule detection sensitivity, reducing false-positive rates, and classifying nodules. However, the universality and interpretability of AI results need further enhancement. Future research should focus on the large-scale validation of new deep learning-based algorithms and multi-center studies to improve the efficacy of AI in lung cancer screening.


Assuntos
Inteligência Artificial , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Detecção Precoce de Câncer , Tomografia Computadorizada por Raios X/métodos , Pulmão , Prognóstico
13.
Sci Rep ; 14(1): 8504, 2024 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-38605094

RESUMO

This work aims to investigate the clinical feasibility of deep learning-based synthetic CT images for cervix cancer, comparing them to MR for calculating attenuation (MRCAT). Patient cohort with 50 pairs of T2-weighted MR and CT images from cervical cancer patients was split into 40 for training and 10 for testing phases. We conducted deformable image registration and Nyul intensity normalization for MR images to maximize the similarity between MR and CT images as a preprocessing step. The processed images were plugged into a deep learning model, generative adversarial network. To prove clinical feasibility, we assessed the accuracy of synthetic CT images in image similarity using structural similarity (SSIM) and mean-absolute-error (MAE) and dosimetry similarity using gamma passing rate (GPR). Dose calculation was performed on the true and synthetic CT images with a commercial Monte Carlo algorithm. Synthetic CT images generated by deep learning outperformed MRCAT images in image similarity by 1.5% in SSIM, and 18.5 HU in MAE. In dosimetry, the DL-based synthetic CT images achieved 98.71% and 96.39% in the GPR at 1% and 1 mm criterion with 10% and 60% cut-off values of the prescription dose, which were 0.9% and 5.1% greater GPRs over MRCAT images.


Assuntos
Aprendizado Profundo , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
14.
BMC Cancer ; 24(1): 438, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594670

RESUMO

PURPOSE: Based on the quantitative and qualitative features of CT imaging, a model for predicting the invasiveness of ground-glass nodules (GGNs) was constructed, which could provide a reference value for preoperative planning of GGN patients. MATERIALS AND METHODS: Altogether, 702 patients with GGNs (including 748 GGNs) were included in this study. The GGNs operated between September 2020 and July 2022 were classified into the training group (n = 555), and those operated between August 2022 and November 2022 were classified into the validation group (n = 193). Clinical data and the quantitative and qualitative features of CT imaging were harvested from these patients. In the training group, the quantitative and qualitative characteristics in CT imaging of GGNs were analyzed by using performing univariate and multivariate logistic regression analyses, followed by constructing a nomogram prediction model. The differentiation, calibration, and clinical practicability in both the training and validation groups were assessed by the nomogram models. RESULTS: In the training group, multivariate logistic regression analysis disclosed that the maximum diameter (OR = 4.707, 95%CI: 2.06-10.758), consolidation/tumor ratio (CTR) (OR = 1.027, 95%CI: 1.011-1.043), maximum CT value (OR = 1.025, 95%CI: 1.004-1.047), mean CT value (OR = 1.035, 95%CI: 1.008-1.063; P = 0.012), spiculation sign (OR = 2.055, 95%CI: 1.148-3.679), and vascular convergence sign (OR = 2.508, 95%CI: 1.345-4.676) were independent risk parameters for invasive adenocarcinoma. Based on these findings, we established a nomogram model for predicting the invasiveness of GGN, and the AUC was 0.910 (95%CI: 0.885-0.934) and 0.902 (95%CI: 0.859-0.944) in the training group and the validation group, respectively. The internal validation of the Bootstrap method showed an AUC value of 0.905, indicating a good differentiation of the model. Hosmer-Lemeshow goodness of fit test for the training and validation groups indicated that the model had a good fitting effect (P > 0.05). Furthermore, the calibration curve and decision analysis curve of the training and validation groups reflected that the model had a good calibration degree and clinical practicability. CONCLUSION: Combined with the quantitative and qualitative features of CT imaging, a nomogram prediction model can be created to forecast the invasiveness of GGNs. This model has good prediction efficacy for the invasiveness of GGNs and can provide help for the clinical management and decision-making of GGNs.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Nomogramas , Tomografia Computadorizada por Raios X/métodos , Invasividade Neoplásica/patologia , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/cirurgia , Adenocarcinoma de Pulmão/patologia , Estudos Retrospectivos
15.
Biomed Phys Eng Express ; 10(3)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38579691

RESUMO

Background.Modern radiation therapy technologies aim to enhance radiation dose precision to the tumor and utilize hypofractionated treatment regimens. Verifying the dose distributions associated with these advanced radiation therapy treatments remains an active research area due to the complexity of delivery systems and the lack of suitable three-dimensional dosimetry tools. Gel dosimeters are a potential tool for measuring these complex dose distributions. A prototype tabletop solid-tank fan-beam optical CT scanner for readout of gel dosimeters was recently developed. This scanner does not have a straight raypath from source to detector, thus images cannot be reconstructed using filtered backprojection (FBP) and iterative techniques are required.Purpose.To compare a subset of the top performing algorithms in terms of image quality and quantitatively determine the optimal algorithm while accounting for refraction within the optical CT system. The following algorithms were compared: Landweber, superiorized Landweber with the fast gradient projection perturbation routine (S-LAND-FGP), the fast iterative shrinkage/thresholding algorithm with total variation penalty term (FISTA-TV), a monotone version of FISTA-TV (MFISTA-TV), superiorized conjugate gradient with the nonascending perturbation routine (S-CG-NA), superiorized conjugate gradient with the fast gradient projection perturbation routine (S-CG-FGP), superiorized conjugate gradient with with two iterations of CG performed on the current iterate and the nonascending perturbation routine (S-CG-2-NA).Methods.A ray tracing simulator was developed to track the path of light rays as they traverse the different mediums of the optical CT scanner. Two clinical phantoms and several synthetic phantoms were produced and used to evaluate the reconstruction techniques under known conditions. Reconstructed images were analyzed in terms of spatial resolution, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), signal non-uniformity (SNU), mean relative difference (MRD) and reconstruction time. We developed an image quality based method to find the optimal stopping iteration window for each algorithm. Imaging data from the prototype optical CT scanner was reconstructed and analysed to determine the optimal algorithm for this application.Results.The optimal algorithms found through the quantitative scoring metric were FISTA-TV and S-CG-2-NA. MFISTA-TV was found to behave almost identically to FISTA-TV however MFISTA-TV was unable to resolve some of the synthetic phantoms. S-CG-NA showed extreme fluctuations in the SNR and CNR values. S-CG-FGP had large fluctuations in the SNR and CNR values and the algorithm has less noise reduction than FISTA-TV and worse spatial resolution than S-CG-2-NA. S-LAND-FGP had many of the same characteristics as FISTA-TV; high noise reduction and stability from over iterating. However, S-LAND-FGP has worse SNR, CNR and SNU values as well as longer reconstruction time. S-CG-2-NA has superior spatial resolution to all algorithms while still maintaining good noise reduction and is uniquely stable from over iterating.Conclusions.Both optimal algorithms (FISTA-TV and S-CG-2-NA) are stable from over iterating and have excellent edge detection with ESF MTF 50% values of 1.266 mm-1and 0.992 mm-1. FISTA-TV had the greatest noise reduction with SNR, CNR and SNU values of 424, 434 and 0.91 × 10-4, respectively. However, low spatial resolution makes FISTA-TV only viable for large field dosimetry. S-CG-2-NA has better spatial resolution than FISTA-TV with PSF and LSF MTF 50% values of 1.581 mm-1and 0.738 mm-1, but less noise reduction. S-CG-2-NA still maintains good SNR, CNR, and SNU values of 168, 158 and 1.13 × 10-4, respectively. Thus, S-CG-2-NA is a well rounded reconstruction algorithm that would be the preferable choice for small field dosimetry.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Radiometria/métodos , Razão Sinal-Ruído , Algoritmos
16.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 461-465, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632067

RESUMO

Objective: To explore the method of accurately estimating the acetabular cup prosthesis coverage rate (hereinafter referred to as "cup coverage rate") in total hip arthroplasty (THA) based on X-ray films, and to determine the effective parameters that can be used to estimate the cup coverage rate. Methods: The three-dimensional printed pelvic models were established based on CT data of 16 healthy pelvis, and the acetabular prosthesis were implanted according to conventional THA procedure. The length and width of the uncovered area of the acetabular cup prosthesis were measured by a modified X-ray recording method with a rotating C-arm X-ray machine, and the cup coverage rate was calculated. Then the differences among the traditional anteroposterior X-ray recording method, the modified method, and actual measurement on pelvic model were statistically analyzed. The correlation between the area of the uncovered area of the prosthesis and its width and length was analyzed by using multiple linear regression analysis. Results: The cup coverage rates of traditional method, modified method, and actual measurement were 78.22%±3.36%, 86.74%±3.61%, and 89.62%±2.62%, respectively, with significant differences ( P<0.05). The results of multiple linear regression analysis showed that the width and length were positively linear with the uncovered area of the prosthesis, and the regression equation was as follows: uncovered area of the prosthesis=-21.192+0.248×width+0.140×length, and the coefficient of determination R 2=0.857, P<0.001. Conclusion: Compared with the traditional method, the modified method can more accurately evaluate the cup coverage rate during THA, and the width of the uncovered area of the prosthesis can be used as an effective reference for the cup coverage rate.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Filme para Raios X , Tomografia Computadorizada por Raios X/métodos
17.
Int J Med Robot ; 20(2): e2633, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38654571

RESUMO

BACKGROUND: Allergic rhinitis constitutes a widespread health concern, with traditional treatments often proving to be painful and ineffective. Acupuncture targeting the pterygopalatine fossa proves effective but is complicated due to the intricate nearby anatomy. METHODS: To enhance the safety and precision in targeting the pterygopalatine fossa, we introduce a deep learning-based model to refine the segmentation of the pterygopalatine fossa. Our model expands the U-Net framework with DenseASPP and integrates an attention mechanism for enhanced precision in the localisation and segmentation of the pterygopalatine fossa. RESULTS: The model achieves Dice Similarity Coefficient of 93.89% and 95% Hausdorff Distance of 2.53 mm with significant precision. Remarkably, it only uses 1.98 M parameters. CONCLUSIONS: Our deep learning approach yields significant advancements in localising and segmenting the pterygopalatine fossa, providing a reliable basis for guiding pterygopalatine fossa-assisted punctures.


Assuntos
Aprendizado Profundo , Fossa Pterigopalatina , Humanos , Fossa Pterigopalatina/diagnóstico por imagem , Fossa Pterigopalatina/anatomia & histologia , Algoritmos , Rinite Alérgica/diagnóstico por imagem , Rinite Alérgica/terapia , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes
18.
Respir Res ; 25(1): 177, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658980

RESUMO

BACKGROUND: Computer Aided Lung Sound Analysis (CALSA) aims to overcome limitations associated with standard lung auscultation by removing the subjective component and allowing quantification of sound characteristics. In this proof-of-concept study, a novel automated approach was evaluated in real patient data by comparing lung sound characteristics to structural and functional imaging biomarkers. METHODS: Patients with cystic fibrosis (CF) aged > 5y were recruited in a prospective cross-sectional study. CT scans were analyzed by the CF-CT scoring method and Functional Respiratory Imaging (FRI). A digital stethoscope was used to record lung sounds at six chest locations. Following sound characteristics were determined: expiration-to-inspiration (E/I) signal power ratios within different frequency ranges, number of crackles per respiratory phase and wheeze parameters. Linear mixed-effects models were computed to relate CALSA parameters to imaging biomarkers on a lobar level. RESULTS: 222 recordings from 25 CF patients were included. Significant associations were found between E/I ratios and structural abnormalities, of which the ratio between 200 and 400 Hz appeared to be most clinically relevant due to its relation with bronchiectasis, mucus plugging, bronchial wall thickening and air trapping on CT. The number of crackles was also associated with multiple structural abnormalities as well as regional airway resistance determined by FRI. Wheeze parameters were not considered in the statistical analysis, since wheezing was detected in only one recording. CONCLUSIONS: The present study is the first to investigate associations between auscultatory findings and imaging biomarkers, which are considered the gold standard to evaluate the respiratory system. Despite the exploratory nature of this study, the results showed various meaningful associations that highlight the potential value of automated CALSA as a novel non-invasive outcome measure in future research and clinical practice.


Assuntos
Biomarcadores , Fibrose Cística , Sons Respiratórios , Humanos , Estudos Transversais , Masculino , Feminino , Estudos Prospectivos , Adulto , Fibrose Cística/fisiopatologia , Fibrose Cística/diagnóstico por imagem , Adulto Jovem , Adolescente , Auscultação/métodos , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Criança , Estudo de Prova de Conceito , Diagnóstico por Computador/métodos , Pessoa de Meia-Idade
19.
Technol Cancer Res Treat ; 23: 15330338241245943, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38660703

RESUMO

BACKGROUND: Hepatocellular carcinoma (HCC) is a serious health concern because of its high morbidity and mortality. The prognosis of HCC largely depends on the disease stage at diagnosis. Computed tomography (CT) image textural analysis is an image analysis technique that has emerged in recent years. OBJECTIVE: To probe the feasibility of a CT radiomic model for predicting early (stages 0, A) and intermediate (stage B) HCC using Barcelona Clinic Liver Cancer (BCLC) staging. METHODS: A total of 190 patients with stages 0, A, or B HCC according to CT-enhanced arterial and portal vein phase images were retrospectively assessed. The lesions were delineated manually to construct a region of interest (ROI) consisting of the entire tumor mass. Consequently, the textural profiles of the ROIs were extracted by specific software. Least absolute shrinkage and selection operator dimensionality reduction was used to screen the textural profiles and obtain the area under the receiver operating characteristic curve values. RESULTS: Within the test cohort, the area under the curve (AUC) values associated with arterial-phase images and BCLC stages 0, A, and B disease were 0.99, 0.98, and 0.99, respectively. The overall accuracy rate was 92.7%. The AUC values associated with portal vein phase images and BCLC stages 0, A, and B disease were 0.98, 0.95, and 0.99, respectively, with an overall accuracy of 90.9%. CONCLUSION: The CT radiomic model can be used to predict the BCLC stage of early-stage and intermediate-stage HCC.


Assuntos
Carcinoma Hepatocelular , Estudos de Viabilidade , Neoplasias Hepáticas , Estadiamento de Neoplasias , Curva ROC , Tomografia Computadorizada por Raios X , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Tomografia Computadorizada por Raios X/métodos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Prognóstico , Adulto , Processamento de Imagem Assistida por Computador/métodos , Área Sob a Curva , 60570
20.
BMC Geriatr ; 24(1): 360, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654207

RESUMO

BACKGROUND: Gastric intramural hematoma is a rare disease. Here we report a case of spontaneous isolated gastric intramural hematoma combined with spontaneous superior mesenteric artery intermural hematoma. CASE PRESENTATION: A 75-years-old man was admitted to our department with complaints of abdominal pain. He underwent a whole abdominal computed tomography (CT) scan in the emergency department, which showed extensive thickening of the gastric wall in the gastric body and sinus region with enlarged surrounding lymph nodes, localized thickening of the intestinal wall in the transverse colon, localized indistinct demarcation between the stomach and transverse colon, and a small amount of fluid accumulation in the abdominal cavity. Immediately afterwards, he was admitted to our department, and then we arranged a computed tomography with intravenously administered contrast agent showed a spontaneous isolated gastric intramural hematoma combined with spontaneous superior mesenteric artery intermural hematoma. Therefore, we treated him with anticoagulation and conservative observation. During his stay in the hospital, he was given low-molecular heparin by subcutaneous injection for anticoagulation therapy, and after discharge, he was given oral anticoagulation therapy with rivaroxaban. At the follow-up of more than 4 months, most of the intramural hematoma was absorbed and became significantly smaller, and the intermural hematoma of the superior mesenteric artery was basically absorbed, which also confirmed that the intramural mass was an intramural hematoma. CONCLUSION: A gastric intramural hematoma should be considered, when an intra-abdominal mass was found to be attached to the gastric wall. Proper recognition of gastric intramural hematoma can reduce the misdiagnosis rate of confusion with gastric cancer.


Assuntos
Hematoma , Artéria Mesentérica Superior , Humanos , Masculino , Idoso , Hematoma/complicações , Hematoma/diagnóstico , Hematoma/diagnóstico por imagem , Artéria Mesentérica Superior/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Gastropatias/complicações , Gastropatias/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA